- CHARGING
For best charging, use special Solid State
Lithium ion Power Battery charger, charging in constant current and
limited voltage. Connect their polarities(+ and -) according to
the marking inside the battery. Charging should be
separated into two stages with constant current, starting
charging is less than 1C electric current (the best charging
current is 0.3 times of rated capacity)
When the battery is fully charged (the
highest setting voltage is 4.25V),change to constant voltage
charging. The charging will stop when the current is less than
1000mA.
When
multiple battery cells are connected in series or
parallel, each cell should be monitored against
voltage overcharging
- DISCHARGING
Single battery discharge is strictly
controlled, please cut off when measured to 2.85V (the best
constant discharge current is 0.3 times for rated
capacity of LCP model and 3 times for LFP model).
¡@ |