CHARGING & DISCHARGING METHOD

¡@

- CHARGING

For best charging, use special Solid State Lithium ion Power Battery charger, charging in constant current and limited voltage. Connect their polarities(+ and -) according to the marking inside the battery.
Charging should be separated into two stages with constant current, starting charging is less than 1C electric current (the best charging current is 0.3 times of rated capacity)

When the battery is fully charged (the highest setting voltage is 4.25V),change to constant voltage charging. The charging will stop when the current is less than 1000mA.

When multiple battery cells are connected in series or parallel, each cell should be monitored against voltage overcharging

- DISCHARGING


Single battery discharge is strictly controlled, please cut off when measured to 2.85V (the best constant discharge current is 0.3 times for rated capacity of LCP model and 3 times for LFP model).

¡@

¡@

¡@

¡@

¡@

¡@

¡@

¡@

¡@

¡@

¡@

¡@

 